- Phone:513.772.0060
- Address:7205 Edington Dr. Cincinnati, OH 45249
SSi’s Shim Port with Shim Stock allows for the collection of carbon needed for analysis of true carbon potential in a furnace.
The shim port is fitted with an extending rod with a probe at the end (see picture in Gallery Tab). The shim stock is wrapped around the surface of the probe, after which the probe is inserted into the furnace. Inside the furnace, carbon is absorbed by the shim stock. After a period of 10 to 65 minutes (depending on the furnace temperature), the probe with shim stock is removed from the furnace. The shim stock can then be analyzed to determine the saturation percentage of carbon. Generally, this analysis is based on a measurement of weight or on changes in the chemical properties of the shim stock.
See SSi’s technical paper “SHIM STOCK ANALYSIS” for more information on measuring the carbon content of the furnace atmosphere.
Part Number 34261 |
Thickness: 0.003 inches (0.07 mm) |
1008/1010 AISI 6″ x 100″ (152.4 mm x 2540 mm) Roll |
Approximately 200 1″ x 3″ (25.4 mm x 76.2 mm) PCS |
Part Number 13497 |
Includes cage and rod-cooling chamber |
Approximately 41.4″ (1000.7 mm) in length when fully extended |
Approximately 29.5” of the rod is exposed beyond the Shim Port assembly when inserted in a furnace access port |
Part Number 13694 |
13 inches longer than standard version |
Includes cage and rod-cooling chamber |
Approximately 54.4″ (1381.76 mm) in length when fully extended |
Approximately 42.5” of the rod is exposed beyond the Shim Port assembly when inserted in a furnace access port |
Product Line | User Manual | Datasheet | Wiring | Other |
---|---|---|---|---|
CAT-100 Carbon Analyzer | PDF | Online | CAT-100 Datasheet | HTPro: Tool For Atmospheric Carbon Potential Analysis – CAT-100 | |
Shim Port | Shim Stock – A review of the procedure | |||