The permanently-mounted continuous gas analyzer can be used for carburizing, neutral and ferritic nitrocarburizing heat treat applications. The measurement of the process gas provides calculated values for %C, KN, KC1. In endothermic based atmospheres, the instrument in conjunction with carbon probes can be used to automatically adjust COF to provide the most precise atmosphere measurement.
1 – Calculation of Kc may have inaccuracies in the presence of ammonia.



| Enhances quality through process repeatability and accuracy |
| On-screen trending chart |
| Auto adjust mode replaces manual adjustment of COF – Probe+IR |
| Sooting, air leaks, water leaks, and radiant tube leaks quickly identified through 3 gas measurement |
| Auto-Calibration integrated into the MGA 6010 |
| Session recording with customizable user names and equipment |
| FNC and Nitriding Calculations with optional H2 Cell |
| Sampling method | Extraction by internal pump (when necessary) |
| Measurement Method (CO, CO2, CH4) | Non-Dispersive Infrared (NDIR) |
| Measurement Method (H2) | Thermal Conductivity |
| Accuracy and repeatability | ± 1% of full scale |
| Recommended Factory Calibration Interval | Annual |
| Flow Meter | Front of panel and also on-screen |
| AC Power Requirements | 90 to 230 VAC, 50 to 60 Hz, 60 Watts |
| Communications | Ethernet, USB(A), USB(B), RS485 Modbus |
| Data Storage | Continuous automatic data logging |
| Data Retrieval | XGA Viewer Software (included) or on-screen |
| Operating Temperature | 32° to 122° F (0° to 50° C) |
| CO: Carbon Monoxide | Range: 0 – 30% |
| CO2: Carbon Dioxide | Range: 0 – 2.0% Optional Range: 0 – 20.0% |
| CH4: Natural Gas/Methane | Range: 0 – 20% |
| Optional H2: Hydrogen | Range: 0 – 100% |
| Calculated % Carbon | Range: 0.1 – 2.00% |
| Suggested COF / PF factors | |
| Onboard Data Acquisition | |
| Enhanced with Nitriding/FNC Calculations | Carbon Potential (KC) Nitriding Potential (KN) |
| COF limits predetermined for % Carbon adjustment |
| Millivolt and temperature limits for furnace gas sampling |
| Switch from probe + IR control to “monitor” mode |
| Product Line | User Manual | Datasheet | Wiring | Other |
|---|---|---|---|---|
| MGA 6010 | PDF | Online | MGA 6010 Datasheet | ||
| MGA 6000 (Legacy Product) | ||||
| XGA Viewer | ||||
| General Info | Atmosphere Measurement and Troubleshooting | |||
| Touchscreen Cleaning Procedure | ||||
| An Overview of Endothermic Generators |